2026 OIR-B1-1802 — Current Form Ready ·Full Photo-Documentation Packs · Most Reports Within 24 Hours ·(877) 699-3299
Guide · Insurance Standards

OIR-B1-1802 · Florida Insurance Form The 2026 Wind Mitigation Form, Explained

Florida's Uniform Mitigation Verification Inspection form is six pages of checkboxes that move real money. Here’s what the current 2026 edition asks, why editions matter to carriers, and how Lunar completes every section.

Coconut palms bending in strong wind under an overcast sky (illustrative image)
Illustrative image — the kind of wind the form is written for

The OIR-B1-1802 — the Uniform Mitigation Verification Inspection form — is how Florida standardized wind-credit documentation: one statewide form that Florida carriers use to apply wind credits. An inspector attests to the wind-resistance features (nine questions on the 2026 form), photographs the evidence, signs under license, and the carrier’s underwriter converts those attestations into the windstorm mitigation discounts Florida law requires in every residential rate filing (§627.0629(1), F.S.), documented on the form prescribed under §627.711(2), F.S. Acceptance and credit decisions always rest with your carrier, per its filed rates and underwriting guidelines.

Because the form is the legal instrument, its edition matters. The current version is mandatory for inspections performed on or after April 1, 2026; superseded editions risk rejection and re-inspection delays. This guide walks you through the current 2026 edition — what it asks, what each section means in plain English, and what you’ll receive when Lunar completes it.

01 The Standard

Why the edition on the form matters

The wind mitigation form is updated periodically by the Florida Office of Insurance Regulation. When the form edition changes, carriers update their intake systems to match. A report submitted on a superseded edition — even if the inspection itself was thorough — risks being kicked back for re-inspection. That’s a delay at exactly the moment you’re trying to bind or renew coverage.

Every Lunar wind mitigation inspection is completed on the current 2026 OIR-B1-1802, with the photo-documentation pack underwriters expect attached — truss, eave, and opening.

Did you know?

The form edition is not cosmetic. It’s the legal instrument your carrier reads. A wind mitigation inspection on an outdated form is like filing a tax return on last year’s 1040 — the data may be correct, but the document gets rejected.

02 The Form

What is the OIR-B1-1802?

The OIR-B1-1802 is the Uniform Mitigation Verification Inspection form, published by the Florida Office of Insurance Regulation (FLOIR). It is the statewide standard for documenting wind-resistant construction features that qualify a home for hurricane-premium discounts under §627.711, Florida Statutes.

What changed in 2026: the Rev. 04/26 form adds the wind-speed region and roof-slope questions, accepts FORTIFIED Home® certificates as documentation, adds a spray-foam deck option, allows performance-based roof-to-wall connectors documented to 386 / 535 / 891 lb allowable uplift, recognises taped deck seams and double-layer underlayment as a sealed roof deck, and adds opening-protection levels D (rated non-glazed doors) and Z (damaged openings). A Rev. 01/12 form completed within five years before April 1, 2026 may still be honored if nothing material has changed; acceptance and credit decisions always rest with your carrier, per its filed rates and underwriting guidelines.

In practical terms, the current form — OIR-B1-1802 (Rev. 04/26), adopted by Rule 69O-170.0155, F.A.C., and mandatory for inspections performed on or after April 1, 2026 — runs six pages. Page 1 collects owner, policy and building data; questions 1 through 9 then cover building code, wind-speed region, roof slope, roof covering, roof deck attachment, roof-to-wall attachment, roof geometry, sealed roof deck/secondary water resistance, and opening protection; pages 5–6 carry the qualified-inspector certification and signatures. At least one photograph or document must accompany every attribute marked in questions 2 through 9, and a FORTIFIED Home® Roof, Silver or Gold certificate may be attached to validate questions 4–6 and 8–9.

  • Published by the Florida Office of Insurance Regulation (FLOIR)
  • Governs premium credits under §627.711, Florida Statutes
  • Completed and signed by a licensed Florida home inspector, general contractor, or professional engineer
  • Valid for up to five years, provided no material changes are made to the structure — across multiple renewal cycles
  • The official form is available through floir.gov (Wind Mitigation Resources)
Wind mitigation inspection at a home under construction with sealed sheathing, St. Johns County
A wind mitigation inspection in progress — St. Johns County
03 The Nine

What the form asks, line by line

Nine questions, each an attestation with photographic evidence — the same nine our inspection documents every visit. Together, they tell the carrier everything it needs to calculate your wind-credit eligibility.

  • 01

    Building code / permit date

    When the roof was built or last permitted — the baseline that scales every other credit on the form. Homes whose original permit application is dated after March 1, 2002 (FBC 2001/2004) — and, on the 2026 form, a separate answer for permits after December 8, 2006 (FBC 2007 and later) — qualify for the newer-code answers; older homes answer “D. Unknown/does not meet” unless in the Miami-Dade/Broward HVHZ under SFBC-94.

  • 02

    Wind-speed region

    New in the 2026 revision: the home’s ASCE 7-22 design wind-speed region — HVHZ, Region 1 (140 mph or more), Region 2 (130–139 mph) or Region 3 (under 130 mph).

  • 03

    Roof slope

    New in the 2026 revision: whether at least two-thirds of the main roof area is 6:12 or steeper.

  • 04

    Roof covering

    The covering type and whether it meets current wind-rating standards, with permit verification. FBC-approved coverings installed under permit carry the credit; unpermitted replacements do not.

  • 05

    Roof deck attachment

    Nail type, size, and spacing holding the deck to the framing — verified in the attic, photographed at the truss.

  • 06

    Roof-to-wall attachment

    Toe-nails, clips, single or double wraps — the connection hierarchy the form records, documented where the connection is visible and photographed.

  • 07

    Roof geometry

    Hip, gable, flat, or mixed — measured and photographed. Hip roofs distribute wind loads more evenly than gable profiles.

  • 08

    Secondary water resistance (SWR)

    A sealed roof-deck barrier — peel-and-stick, taped seams, a double underlayment layer, or spray foam at the seams — that keeps water out if the covering fails. SWR is difficult to retrofit, but when present it can earn a credit.

  • 09

    Opening protection

    Impact ratings for every window, door, and skylight — documented per opening, at the classification level the form requires.

Metal hurricane clips and connector straps at the roof-to-wall connection inside an attic
Hurricane clips at the roof-to-wall connection — the photo evidence behind attestation 04

Key takeaway

  • Features are documented, not scored. The inspector attests to what’s there; the carrier applies the credit schedule. A wind mitigation inspection is an observation report, not a pass/fail exam.
  • Photo evidence is mandatory. Every attestation is backed by photographs — attic trusses, roof-to-wall connectors, opening labels, and exterior geometry.
  • One form, statewide. The OIR-B1-1802 is the statewide form Florida carriers use to apply wind credits; acceptance and credit decisions always rest with your carrier, per its filed rates and underwriting guidelines.
04 The Process

How Lunar documents the form

A wind mitigation is a field documentation exercise — the inspector physically verifies each of the nine form questions and photographs the evidence the carrier expects. Here’s how Lunar approaches it.

Photo-documentation packs

Every Lunar wind mitigation ships with a photo-documentation pack — attic trusses, roof-to-wall connectors, roof covering close-ups, and labeled opening shots. These aren’t for your file cabinet; they’re the evidence behind each attestation, so an underwriter reviewing your file can see it.

Licensed and signed

Brian Walker personally performs and signs every wind mitigation under FL License #HI14111. The form carries a licensed inspector’s signature — never a subcontracted crew. One inspector, one standard, every visit.

Digital delivery

The completed OIR-B1-1802 and photo pack are delivered digitally, typically within 24 hours — ready to submit to your carrier, agent, or underwriter.

05 Deliverables

What you receive

Every Lunar wind mitigation delivers a complete, carrier-ready package — not just the form, but the photo evidence behind each answer, so an underwriter reviewing your file can see it.

  • 2026 OIR-B1-1802 — the current statewide edition, completed in full with all nine questions
  • Photo evidence pack — attic trusses, roof-to-wall connectors, covering close-ups, opening labels, and exterior geometry
  • Signed under license — FL Home Inspector License #HI14111, Certified Master Inspector
  • Valid for up to five years (no material changes) — across multiple renewal cycles with your carrier
  • Digital delivery, typically within 24 hours — ready to forward to your agent, carrier, or underwriter
Good to know

Need a 4-point inspection too? Your carrier may want both. Our insurance bundle combines wind mitigation + 4-point + roof certification in a single visit — one trip, one report package, one day.

Ready to get on the current form? Report typically within 24 hours, bundled with 4-point if you need both.
Schedule Inspection
06 FAQ

Common questions about the form

Why does the form edition matter?

The current edition (Rev. 04/26) is mandatory for inspections performed on or after April 1, 2026 (Rule 69O-170.0155, F.A.C.). A report submitted on an outdated edition risks being kicked back for re-inspection at exactly the moment you’re trying to bind coverage. Every Lunar wind mitigation is completed on the current 2026 OIR-B1-1802.

Where can I see the official form?

The OIR-B1-1802 is published by the Florida Office of Insurance Regulation — available through floir.gov (Wind Mitigation Resources). What you’re reading here is a plain-English guide to what it asks; the form itself is the legal document your inspector completes and signs.

Do I need a new inspection because the form updated?

Not necessarily — an existing report remains generally valid for its five-year window. But if your carrier requests the current edition, or you’ve upgraded a feature since your last inspection, a new inspection on the current form is the clean answer.

Does Lunar charge more for the current form?

No — the current edition is simply what a wind mitigation inspection is. Flat pricing is on the pricing page.

What if my home doesn’t qualify for any credits?

The inspection still documents what’s there — honestly. Some homes have construction features that don’t earn credits under the current schedule, and that’s a legitimate outcome. The report tells your carrier the truth, and you’ll know exactly which upgrades (if any) would change the result.

Next steps

If your carrier has requested a wind mitigation — or you want to find out what credits your home qualifies for — schedule it early. A completed OIR-B1-1802 on the current edition, with photo documentation, documents each credit-qualifying feature your home has before you bind or renew coverage.

Schedule a wind mitigation inspection, bundle the 4-point if your carrier wants both, and we’ll deliver the insurer-ready report, typically within 24 hours. Not sure what you need? Find My Inspection takes under a minute.

“A rate filing for residential property insurance must include actuarially reasonable discounts, credits, or other rate differentials, or appropriate reductions in deductibles, for properties on which fixtures or construction techniques demonstrated to reduce the amount of loss in a windstorm have been installed or implemented.”

§627.0629(1), Florida Statutes

This resource is provided for general educational purposes for Florida homeowners, buyers, and investors. It is not legal, engineering, or insurance advice, and it is not a substitute for a professional inspection of a specific property, nor for the official form and its instructions. Requirements, form instructions, carrier guidelines, and underwriting interpretations may change; the applicable form edition, official instructions, available documentation, observed conditions, and carrier requirements control each individual inspection. Lunar does not author the state form, does not control carrier interpretation, and cannot guarantee any underwriting outcome. Wind mitigation savings vary by carrier, policy, and home features and are not guaranteed.

Share